    The Principles of Energy Efficient Microclimate Provision in the Skyscraper “Biotecton” of 1 km Height
    (EUSER, 2018-12) Krivenko, O.; Mileikovskyi, V.; Tkachenko, T
    The article deals with the formation of a healthy human living environment in superstructure buildings with the requirements of indoor air quality, environmental and constructive safety. The results of the development of "Biotecton" - an ultra-high-rise multi-functional building (the height is 1000 m) are presented. In order to effectively overcome the wind and seismic loads, the principles of the structure of the natural form (Gramineae stems, Triticale) are used. It is a multi-tiered spatial structure, in the nodes of which there are dampers for limiting oscillatory movements. For solving the problems of increasing the energy efficiency of ventilation and air conditioning, the use of air from height 1000 m with the minimum of anthropogenic pollution is investigated. Two mechanisms of the movement of air in a superstructure were investigated: natural impulses (under the action of gravitational pressure and wind) and mechanical (fans). It is shown that the natural pressure is insufficient for air movement. The mechanical impulse is necessary, but its energy requirement can be compensated by a renewable energy source - wind turbines with a total capacity of 5.3 MW. For high air quality, the use of "oxygen gardens" in green areas, which are evenly spaced along the entire height of the building, is explored. The study proposed a list of plants that effectively clean air from pollution, sequestrate excess CO2, enrich the air with oxygen and release phytoncides that effectively fight against pathogenic microorganisms.
  • Документ
    New Approach for Estimation of Zonal Efficiency of Air Exchange Organization
    (Science Publishing Corporation, 2018) Dovhaliuk, Volodymyr; Mileikovskyi, Viktor
    Energy efficiency of buildings is dependent on air exchange organization. There are different methods for efficiency estimation of it. As it is shown in literature review, they have significant limitations including non-obvious physical meaning, which cause problems in validation of the results. Certain of them are not acceptable for zonal ventilation in rooms. Previous author’s work introduces new approach for the efficiency estimation of air exchange in a single-zone or multi-zonal rooms, which has obvious physical meaning – relation of demands and supplied potentials. It provides the efficiency value for whole room only. In this work, by the similar approach, a method is proposed for estimation of zonal air exchange efficiency in different kind of rooms for each occupied zone separately. Additional definitions are introduced for the parameters and demands estimation in each occupied zone. The example of efficiency estimation of air exchange in a museum room with constant air volume system of air conditioning is solved. Sheltering of the keeping zone is recommended for the maximum air exchange efficiency.
  • Документ
    Метод розрахунку викідів парникових газів від експлуатації інженерних систем будівель
    (КНУБА, 2020) Кордюков, М. І.
    Зниження викидів парникових газів у даний час є пріоритетним завданням людства для зменшення кліматичних змін. Інженерні системи будівель (опалення, вентиляція, кондиціонування повітря, освітлення та ін.) дають значний внесок у вуглецевий слід. Методика, запропонована в цій статті, дає можливість оцінити величину викидів від кожної з систем і намітити шляхи їхнього зниження. Особливістю запропонованої методики є наступні положення. Розглядається внесок у викиди парникових газів усіх інженерних систем, що забезпечують комфортність приміщень будівлі. Комфортність приміщень будівлі розглядається відповідно до EN 15251. Параметри зовнішнього середовища визначаються відповідно до методики автора. При розробці методики прийняті такі спрощення. Не розглядається система зволоження повітря в зимовий час, тоді як осушення повітря в літній період при кондиціонуванны повітря враховано. Коефіцієнти робочого часу систем дані для прикладу. Нормативні показники розглядаються відповідно до ДСТУ Б А.2.2-12. Методика може використовуватися як для оцінки величини викидів СО2 наявних будівель, так і для вибору варіанту формування мікроклімату проектованої будівлі. Особливо корисною методика може бути для вибору доцільної технології формування мікроклімату при реконструкції будівлі шляхом порівняння кількості викидів від різних варіантів.