    New Approach for Refined Efficiency Estimation of Air Exchange Organization
    (Science Publishing Corporation, 2018) Dovhaliuk, Volodymyr; Mileikovskyi, Viktor
    In the modern conditions, energy efficiency is one of the most important world problems. One of the important factors influencing the overall energy efficiency of buildings is air distribution in rooms. Literature review shows different options of efficiency estimation of air exchange with significant limitations. Some of them have non-obvious physical meaning. Certain of them do not take into account possible room zoning. Consideration of turbulence intensity in the efficiency estimation was not found. In this work, we propose an approach to estimate the air exchange efficiency in different kind of rooms. It is a relation of minimum room demands and inlet air potentials. Additional definitions are introduced for the parameters and demands estimation. The mechanical energy of the air is used for the estimation, which includes the energy of averaged motion and turbulent pulsation. Special approach is offered for turbulence intensity computation for energy calculations. The example of efficiency estimation of air exchange in a museum room with constant air volume system of air conditioning is solved.
  • Документ
    New Approach for Estimation of Zonal Efficiency of Air Exchange Organization
    (Science Publishing Corporation, 2018) Dovhaliuk, Volodymyr; Mileikovskyi, Viktor
    Energy efficiency of buildings is dependent on air exchange organization. There are different methods for efficiency estimation of it. As it is shown in literature review, they have significant limitations including non-obvious physical meaning, which cause problems in validation of the results. Certain of them are not acceptable for zonal ventilation in rooms. Previous author’s work introduces new approach for the efficiency estimation of air exchange in a single-zone or multi-zonal rooms, which has obvious physical meaning – relation of demands and supplied potentials. It provides the efficiency value for whole room only. In this work, by the similar approach, a method is proposed for estimation of zonal air exchange efficiency in different kind of rooms for each occupied zone separately. Additional definitions are introduced for the parameters and demands estimation in each occupied zone. The example of efficiency estimation of air exchange in a museum room with constant air volume system of air conditioning is solved. Sheltering of the keeping zone is recommended for the maximum air exchange efficiency.