Документ Methods Analysis for assessing the effectiveness of the air exchange organization(КНУБА, 2018) Dovgalyuk, V.; Sitnicka, A.; Tereschuk, M.This article provides the review of scientific literature on the estimation of ventilation systems efficiency. It has been shown that energy efficiency requirements are becoming increasingly important for building microclimate systems. The operating costs of ventilation and air conditioning systems in some buildings can reach 50% of the total cost. The state of the airspace directly affects the health of people and the productivity of their work. Therefore, the question of assessing the quality of ventilation and air conditioning systems at the design stage is relevant. There are different approaches to determining the efficiency of air exchange in the room. Modern approaches to assessing the effectiveness of ventilation in Ukraine, the EU and the US are significantly different, requiring an analysis and understanding of the advantages and disadvantages of each. The evaluation of the air exchange efficiency using the KL coefficient is based on the construction of an approximate mathematical model of heat and mass transfer processes in the room. The methods of its analytical determination are developed. However, the coefficient KL does not allow to evaluate the efficiency of ventilation systems with variable air flow, the use of KL is problematic for height uniform distribution of temperature in the room. European approaches to assessing the effectiveness of ventilation are based on the assessment of the average CO2 concentration in the room or the average concentration of CO2 in the service area. The concept of air "age" is also used. It is impossible to estimate the effectiveness of ventilation by the formation of temperature and humidity fields indoors according to European methods. US standards use indoor air quality and energy consumption to compare Evz ventilation efficiency. However, the determination of the efficiency of the air distribution Ez, on which the value of Evz depends, is carried out in a simplified manner. All existing techniques do not allow to determine the intensity of air turbulence in the room. For this purpose, we need to develop criteria for assessing the effectiveness of ventilation, which takes into account the majority of factors that affect the microclimate in the room.Документ New Approach for Estimation of Zonal Efficiency of Air Exchange Organization(Science Publishing Corporation, 2018) Dovhaliuk, Volodymyr; Mileikovskyi, ViktorEnergy efficiency of buildings is dependent on air exchange organization. There are different methods for efficiency estimation of it. As it is shown in literature review, they have significant limitations including non-obvious physical meaning, which cause problems in validation of the results. Certain of them are not acceptable for zonal ventilation in rooms. Previous author’s work introduces new approach for the efficiency estimation of air exchange in a single-zone or multi-zonal rooms, which has obvious physical meaning – relation of demands and supplied potentials. It provides the efficiency value for whole room only. In this work, by the similar approach, a method is proposed for estimation of zonal air exchange efficiency in different kind of rooms for each occupied zone separately. Additional definitions are introduced for the parameters and demands estimation in each occupied zone. The example of efficiency estimation of air exchange in a museum room with constant air volume system of air conditioning is solved. Sheltering of the keeping zone is recommended for the maximum air exchange efficiency.Документ New Approach for Refined Efficiency Estimation of Air Exchange Organization(Science Publishing Corporation, 2018) Dovhaliuk, Volodymyr; Mileikovskyi, ViktorIn the modern conditions, energy efficiency is one of the most important world problems. One of the important factors influencing the overall energy efficiency of buildings is air distribution in rooms. Literature review shows different options of efficiency estimation of air exchange with significant limitations. Some of them have non-obvious physical meaning. Certain of them do not take into account possible room zoning. Consideration of turbulence intensity in the efficiency estimation was not found. In this work, we propose an approach to estimate the air exchange efficiency in different kind of rooms. It is a relation of minimum room demands and inlet air potentials. Additional definitions are introduced for the parameters and demands estimation. The mechanical energy of the air is used for the estimation, which includes the energy of averaged motion and turbulent pulsation. Special approach is offered for turbulence intensity computation for energy calculations. The example of efficiency estimation of air exchange in a museum room with constant air volume system of air conditioning is solved.Документ Експериментальні дослідження осушення повітря з використанням синтетичних напівпроникних мембран в системах кондиціонування повітря(КНУБА, 2018) Задоянний, О. В.; Євдокименко, Ю. М.Зберігання сільськогосподарської продукції в регламентованих умовах пот`ребує цілорічного та цілодобового підтримання параметрів повітряного середовища – температури та відносної вологості – у певних діапазонах, які встановлюються технологічним регламентом для кожного виду такої продукції. Для підтримання відносної вологості системи кондиціонування повітря обладнують секціями осушення. У процесі осушення в системах кондиціонування повітря витрачається найбільша кількість енергії порівняно з іншими стадіями обробки повітря. Сучасні дослідження в області технологічного кондиціонування повітря направлені на підвищення ефективності перебігу процесів обробки повітря з одночасним зменшенням енерговитрат. В останніх дослідженнях застосовують в основному адсорбційні процеси осушення, які не зменшують радикально енерговитрати. Напівпроникні мембрани не набули широкого застосування в системах технологічного кондиціонування повітря, але мають реальну перспективу забезпечити енергоощадне осушення в системах кондиціонування повітря порівняно з традиційними конденсаційним та адсорбційним способами. Вони дозволяють крім зниження витрати енергії на осушення повітря уникнути негативного явища обмерзання теплообмінника. У даній роботі наведено результати експериментальних досліджень щодо оцінки можливості застосування напівпроникних мембран для осушення повітря складу для зберігання сільськогосподарської продукції. Наведено результати експериментальних досліджень зменшення вологовмісту в секції мембранного осушення, наведена експериментальна залежність продуктивності осушення від питомого повітряного навантаження на мембрану. Отримані результати дають можливість практичного застосування мембранного осушення при послідовній багатоступеневій обробці повітря в системах кондиціонування з чергуванням стадій охолодження та мембранним осушення повітря.Документ Метод розрахунку викідів парникових газів від експлуатації інженерних систем будівель(КНУБА, 2020) Кордюков, М. І.Зниження викидів парникових газів у даний час є пріоритетним завданням людства для зменшення кліматичних змін. Інженерні системи будівель (опалення, вентиляція, кондиціонування повітря, освітлення та ін.) дають значний внесок у вуглецевий слід. Методика, запропонована в цій статті, дає можливість оцінити величину викидів від кожної з систем і намітити шляхи їхнього зниження. Особливістю запропонованої методики є наступні положення. Розглядається внесок у викиди парникових газів усіх інженерних систем, що забезпечують комфортність приміщень будівлі. Комфортність приміщень будівлі розглядається відповідно до EN 15251. Параметри зовнішнього середовища визначаються відповідно до методики автора. При розробці методики прийняті такі спрощення. Не розглядається система зволоження повітря в зимовий час, тоді як осушення повітря в літній період при кондиціонуванны повітря враховано. Коефіцієнти робочого часу систем дані для прикладу. Нормативні показники розглядаються відповідно до ДСТУ Б А.2.2-12. Методика може використовуватися як для оцінки величини викидів СО2 наявних будівель, так і для вибору варіанту формування мікроклімату проектованої будівлі. Особливо корисною методика може бути для вибору доцільної технології формування мікроклімату при реконструкції будівлі шляхом порівняння кількості викидів від різних варіантів.